Microcomputer controlled bending and torsion testing machine

Main functions:

        Test insulator bend and twist test (electronic control)。


Performance characteristics:

1.It can do 1 point bending test of insulators, and also can do 4 point automatic bending test in the circular direction。

2.This machine has 1 station, experimental bending and torsion test。

3.Lifting space adjustment adopts screw drive, linear guide guide, smooth transmission without sliding。

4.Real-time display of test force and deformation data。

5.Real-time display of test force-deformation curve。

6.It has the function of curve analysis, comparison, simulation and amplification。

7. When torsion is equipped with bolt locking flange function, easy to operate。

8.High measurement accuracy, high control accuracy, low noise。


Vertical meet the standard:                                

GB/Z 24839-2009

GB/T775.3-2006 

GB/T8287.1-2008 

DL/T1048-2007


Horizontal type meets the standard:

GB/T 4109-2008 

GB/T22674-2008 

GB/T21429-2008

GB/T 26166-2010


Technical parameters:

Model BTT204A BTT304A BTT504A-B BTT504A-C BTT105A BTT105A 

最大负荷(kN)                        20            30                 50                  50                100               100

Maximum torque (kN.m)                    10            10                 10                  15                 20                 30

Effective force measurement range (kN) 2% ~ 100%

The accuracy of force measurement is within ±1% of the indicated value / ±0 of the indicated value.5%以内

Maximum load / 250,000 yards with constant resolution

Electronic speed closed-loop control Stress Stress test: 1 ~ 30 n/was.S-1 Strain:0.00025~0.25/S

Deformation measurement accuracy within ±1% of the indicated value / ±0 of the indicated value.5%以内

The displacement measurement accuracy is within ±1% of the indicated value / ±0 of the indicated value.5%以内

Effective test space (mm) 0 ~ 200,1300,2000,3000,4000,5000 (according to customer requirements)

Effective torsion Angle 0 ~ 30°

Piston stroke (mm) 250 ~ 2000

Insulator installation maximum diameter (mm) Ф Ф Ф Ф Ф Ф 800 600 400 300 200 10000

Reverse installation insulator diameter (mm) 200 300 500 800    

Clamping way T slot screw thread connection

Protection function electronic limit protection function/exceeds 3% of the maximum load, automatic protection function

Power Supply (kW) 2.5                       4                      4                              5

Host weight (kg) of about 2200 about 2800 about 5000 around 8000